Clamp · Reverser · Mold Carrier · Die spotting press · Mold Switch
SY-CLAMP
TAEDO SYSTEM
Product
CUSTOMER
Please feel free to contact us if you have any questions.
TAEDO SYSTEM Co., Ltd.
TEL. +82-32-822-1921
~3
FAX. +82-32-822-1924
EMAIL. taedo684@hanmail.net
BUSAN business office
TEL. +82-51-988-1921
FAX. +82-51-988-1924
Summary
It has a single acting cylinder structure and is operated by hydraulic pressure when clamping, but it is returned by spring when clamping.
The pressure is the first pressure increase in proportion to the cylinder area at the operating pressure, and the second pressure is boosted by the lever.
CYLINDER is in surface contact with the mold for excellent clamping force.
Structure
Nominal method
SY ①T - ② - A
① | Tightening force |
2 | 2 TON |
4 | 4 TON |
6 | 6 TON |
10 | 10 TON |
16 | 16 TON |
25 | 25 TON |
② | Mold height : H(mm) |
Modalities
Modalities / Forms | SY-2 | SY-4 | SY-6 | SY-10 | SY-16 |
Interanal pressure ( Kgf/㎠ ) | 275 | ||||
Maximum applied pressure ( Kgf/㎠ ) | 185 | ||||
Cohesion (TON) | 2 | 4.2 | 6 | 10.5 | 16.8 |
Stroke (mm) | 5 | 5 | 7 | 8 | 8 |
Required oil quantity (㎖) | 5.6 | 11.7 | 24.2 | 46.7 | 74.8 |
Applied temperature scope (℃) | -5 ~ 60℃ | ||||
Oil used | General hydraulic oil | ||||
주① Weight (Kgf) | 1.2 | 2.2 | 3.5 | 6.4 | 12.2 |
※ 주① Weight H = 100 mm
Measurement
Form | a | b | d | E | F | G | N | I | J | MIN. K | MIN. M | flux (㎖) | |
UNCLAMP | CLAMP | ||||||||||||
SY- 2 | 2 | 3 | 18 | 42 | 58 | 49 | 10 | 12 | 38 | 8 | 12 | 5.6 | 4.3 |
SY- 4 | 2 | 3 | 25 | 60 | 73 | 56 | 17.5 | 13 | 59 | 10 | 17 | 11.7 | 7.5 |
SY- 6 | 2.5 | 4.5 | 30 | 72.8 | 88 | 64 | 17.5 | 5 | 64 | 14 | 20 | 24.2 | 15.6 |
SY-10 | 3 | 5 | 40 | 95 | 108 | 77 | 20 | 15 | 79 | 17 | 28 | 46.7 | 9.2 |
SY-16 | 3 | 5 | 50 | 120 | 146 | 86 | 20 | 15 | 89 | 20 | 32 | 74.8 | 46.7 |